Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 13: 595-607, 1967;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bowers, G. N.
Right arrow Articles by McComb, R. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bowers, G. N., Jr.
Right arrow Articles by McComb, R. B.

Clinical Chemistry, Vol 13, 595-607, Copyright © 1967 by the American Association for Clinical Chemistry

Precision Estimates in Clinical Chemistry

I. Variability of Analytic Results in a Survey Reference Sample Related to the Use of a Nonhuman Serum Alkaline Phosphatase

G. N. Bowers Jr. 1, M. L. Kelley 1, and R. B. McComb 1

1 Clinical Chemistry Laboratory, Hartford Hospital, Hartford, Conn.

The precision of replicate analyses for alkaline phosphataseactivity measured on a survey reference sample was extremely poor. The reference sample's enzyme itself became suspect and was demonstrated to be sensitive to alkaline denaturation-in sharp contrast to the stability of the alkaline phosphatasesfound in human serum. The stability and chemical reactivity of the phosphatases present in this reference sample and in pooled frozen human serum, as well as those found in 4 partially purified nonhuman preparations and 4 commercial serum control materials, were investigated with regard to heat and alkaline denaturation, electrophoretic migration, and inhibition by phosphate, EDTA, and L-pheflylalanine. It was concluded that criteria of stability and chemical reactivity, as well as more detailed information concerning the source of enzymes utilized in reference samples and control materials, are needed. On the basis of these studies, reliance on commercial serum enzyme control materials as an enzyme "standard" cannot be endorsed.

Submitted on February 2, 1967
Accepted on March 1, 1967







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1967 by the American Association for Clinical Chemistry.