Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 14: 132-144, 1968;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Savory, J.
Right arrow Articles by Mushak, P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Savory, J.
Right arrow Articles by Mushak, P.

Clinical Chemistry, Vol 14, 132-144, Copyright © 1968 by the American Association for Clinical Chemistry

An Improved Procedure for the Determination of Serum Ethanol by Gas Chromatography

John Savory 1, F. William Sunderman Jr. 1, Norris O. Roszel 1, and Paul Mushak 1

1 Pathology Department, University of Florida College of Medicine, Gainesville, Fla. 32601.

A modification of the gas chromatographic procedure of Natelson and Stellate has been developed which enables analyses of serum ethanol to be performed with increased sensitivity, precision, and convenience. Serum (50 µl.) is dehydrated by injection onto anhydrous copper sulfate in a stoppered tube at 80° in a water-jacketed rotary mixing apparatus. After 2 min., ethanol vapor is swept by a stream of helium into a gas chromatographic column packed with a mixture of Flexol 8N8, diisodecylphthalate, propyleneglycol 600, and firebrick C-22. Ethanol emerges from the column after a mean retention time of 6.7 min. and is measured by a hydrogen-flame ionization detector. The coefficient of variation of replicate analyses is 2.0%. The recovery of ethanol added to serum is 98.7 ± 3.8%. The limit of sensitivity for the detection of ethanol in serum is 0.1 mg./100 ml., and assay can be made in the presence of constituents which are normally present in serum, and volatile compounds which are commonly encountered in clinical toxicology. Analyses of serum ethanol by gas chromatography provide close correlations with measurements by the alcohol dehydrogenase reaction.

Submitted on June 12, 1967
Accepted on August 3, 1967







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1968 by the American Association for Clinical Chemistry.