Clinical Chemistry, Vol 15, 30-30, Copyright © 1969 by the American Association for Clinical Chemistry
The article "The Determination of Triglycerides in Plasma and Tissues" by Vishwanath M. Sardesai and Joan A. ManningClin.. (Chem. 14, 156 (1968)contains three errors.
On p. 157 under Materials: Reagent 3 should read Alcoholic potassium hydroxide ... with 95% ethyl alcohol. Working solution: dilute 100 ml of stock solution to 50 ml with 95% alcohol on day of use.
On p. 157 under Materials: Reagent 6 should read Sodium arsenite, 0.5 M.
On p. 158, line 9: ... glycerol released on saponification). After exactly 10 min., the oxidation was stopped by the addition of 0.1 ml sodium arsenite. Several minutes later....