Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 16: 39-43, 1970;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Babson, A. L.
Right arrow Articles by Megraw, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Babson, A. L.
Right arrow Articles by Megraw, R. E.

Clinical Chemistry, Vol 16, 39-43, Copyright © 1970 by the American Association for Clinical Chemistry

New Amylase Substrate and Assay Procedure

Arthur L. Babson 1, Susan A. Tenney 1, and Robert E. Megraw 1

1 The Warner-Lambert Research Institute, Morris Plains, N. J. 07950.

This report describes a new procedure for serum amylase assay. A novel substrate, dyed amylopectin, is used that combines the advantages of saccharogenic and amyloclastic methods. Serum amylase hydrolyzes the dyed amylopectin into ethanol-soluble fragments, which are quantified colorimetrically after serum proteins and unhydrolyzed substrate are precipitated with alcoholic tannic acid. The substrate is prepared by coupling Reactone Red 2B to amylopectin in alkaline solution. Unreacted dye is removed by gel filtration. The clear red solution of dyed amylopectin is buffered and diluted to a standard concentration; it can be preserved indefinitely by lyophilization. The assay procedure is the following: 0.2 ml serum is added to 1 ml substrate at 37°C. After incubation for 10 min, 5 ml of alcoholic tannic acid are added, and the mixture is centrifuged. Absorbance of the supernatant solution at 540 nm is a linear function of amylase activity. Serum blanks are not required. The results correlate well with the saccharogenic assay of Somogyi.

Submitted on July 9, 1969
Accepted on August 27, 1969







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1970 by the American Association for Clinical Chemistry.