Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 16: 990-997, 1970;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Logan, J. E.
Right arrow Articles by Sunderland, M. L. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Logan, J. E.
Right arrow Articles by Sunderland, M. L. E.

Clinical Chemistry, Vol 16, 990-997, Copyright © 1970 by the American Association for Clinical Chemistry

Assessment of Two Blood-Analyzer Systems Intended for Diagnostic Testing in the Physician's Office

J. E. Logan 1 and M. L. E. Sunderland 1

1 Clinical Laboratories, Canadian Communicable Disease Centre, Department of National Health and Welfare, Ottawa, Ont., Canada.

We have assessed the Bio-Dynamics "Unitest System" and the Dow Chemical "Diagnostest." Day-to-day reproducibility and within-day precision of the Unitest uric acid and urea nitrogen kits were beyond acceptable limits of error. For Diagnostest, day-to-day reproducibility of bilirubin was outside these limits for two concentrations of bilirubin, one each for uric acid and cholesterol. The Unitest kit gave falsely high readings for cholesterol such that incorrect diagnoses could result. The Diagnostest cholesterol procedure gave values significantly lower than those obtained with the AutoAnalyzer. With Unitest, low results were found on specimens with supranormal uric acid; with Diagnostest low results were obtained for supranormal concentrations of urea nitrogen. Both systems yielded acceptable results for glucose and hemoglobin. We conclude that personnel not technically trained could not obtain reliable data with these systems.


Key Words: Unitest System • Diagnostest • AutoAnalyzer • "packaged" analyses