Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 17: 301-306, 1971;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Savory, J.
Right arrow Articles by Sobel, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Savory, J.
Right arrow Articles by Sobel, R. E.

Clinical Chemistry, Vol 17, 301-306, Copyright © 1971 by the American Association for Clinical Chemistry

Automated Procedure for Simultaneously Measuring Total Globulin and Total Protein in Serum

John Savory 1, M. Geraldine Heintges 1, and Robert E. Sobel 1

1 Department of Pathology, University of Florida College of Medicine, Gainesville, Fla. 32601.

An automated continuous-flow procedure has been developed for simultaneously measuring total serum protein and globulin. The method for total protein is a minor modification of an existing automated method in which the biuret reagent is used. Total globulin is measured by reaction with glyoxylic acid, and standardized with N-acetyltryptophan. An empirical factor relating concentration of N-acetyltryptophan to human globulin has been derived. Values for total serum globulin obtained by this new automated procedure correlate closely with values obtained by electrophoresis, but do not agree with values obtained by use of procedures involving binding of anionic dye. Recovery of gamma globulin added to serum is essentially quantitative; the day-to-day precision (CV) is 4.31%.


Key Words: N-acetyltryptophan as a reference material • comparison with dye-binding and other procedures • glyoxylic acid reaction • normal values • AutoAnalyzer • biuret reaction

Submitted on November 25, 1970
Accepted on January 19, 1971