Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 17: 403-410, 1971;
This Article
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Young, D. S.
Right arrow Articles by Cotlove, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Young, D. S.
Right arrow Articles by Cotlove, E.

Clinical Chemistry, Vol 17, 403-410, Copyright © 1971 by the American Association for Clinical Chemistry

Biological and Analytic Components of Variation in Long-Term Studies of Serum Constituents in Normal Subjects

IV. Results of a Study Designed to Eliminate Long-Term Analytic Deviations

D. S. Young 1, Eugene K. Harris 1, and Ernest Cotlove 1

1 Clinical Pathology Department, Clinical Center, and the Laboratory of Applied Studies, Division of Computer Research and Technology, National Institutes of Health, Bethesda, Md. 20014.

Blood was sampled from nine healthy subjects weekly for 10 weeks, under controlled conditions. Eighteen serum constituents were measured in duplicate in each sample on a single occasion. In this way analytic variation was minimized. Considerable variations in mean values and standard deviations of results were observed among the subjects. Physiological control of serum calcium and magnesium concentrations appeared to be more precise than duplicate determinations in the laboratory. Compared with a previous study from this laboratory, significantly different estimates of personal variation were noted for sodium, chloride, urea nitrogen, cholesterol, and LDH in a group matched by age, race, and sex. At the same time, the present study group, homogenous with respect to these demographic factors (and also occupation) showed as great a diversity in the mean concentrations of most constituents as was seen earlier in a larger, more heterogenous group of normal individuals. These findings indicate that certain blood parameters depend more on personal characteristics than on broad demographic factors.


Key Words: multiphasic screening • "profiling" • AutoAnalyzer • variance • homeostasis • group vs. personal norms

Submitted on February 17, 1971
Accepted on March 8, 1971




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
R. Rej
Clinical Chemistry through Clinical Chemistry: A Journal Timeline
Clin. Chem., December 1, 2004; 50(12): 2415 - 2458.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
W. J. Shih, P. S. Bachorik, J. A. Haga, G. L. Myers, and E. A. Stein
Estimating the Long-Term Effects of Storage at -70 {degrees}C on Cholesterol, Triglyceride, and HDL-Cholesterol Measurements in Stored Sera
Clin. Chem., March 1, 2000; 46(3): 351 - 364.