Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 17: 440-441, 1971;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ceriotti, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ceriotti, G.

Clinical Chemistry, Vol 17, 440-441, Copyright © 1971 by the American Association for Clinical Chemistry

Blood Glucose Determination without Deproteinization, with Use of o-Toluidine in Dilute Acetic Acid

Giovanni Ceriotti 1

1 Laboratorio Centrale di Analisi, Ospedale Civile di Padova (Italy).

A method is described for determining glucose in 25 µl of plasma. o-Toluidine is used in weak acetic acid solution. Addition of the emulsifier "Cremophor" obviates the need for deproteinization. The reaction is complete after 15 min at 100°C, and the color is stable for longer than 24 h. The blank is almost colorless. The reagent is stable, colorless, not viscous, and convenient to handle.

Submitted on November 23, 1970
Accepted on March 9, 1971







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1971 by the American Association for Clinical Chemistry.