Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 17: 686-695, 1971;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burtis, C. A.
Right arrow Articles by Anderson, N. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burtis, C. A.
Right arrow Articles by Anderson, N. G.

Clinical Chemistry, Vol 17, 686-695, Copyright © 1971 by the American Association for Clinical Chemistry

Increased Rate of Analysis by Use of a 42-Cuvet GeMSAEC1 Fast Analyzer

C. A. Burtis 1, W. F. Johnson 1, J. E. Attrill 1, C. D. Scott 1, N. Cho 1, and N. G. Anderson 1

1 Molecular Anatomy (MAN) Program,2 Oak Ridge National Laboratory,3 Oak Ridge, Tenn. 37830.

Sample analysis rate for a GeMSAEC Fast Analyzer is directly proportional to the number of sample cuvets contained in each rotor. GeMSAEC Fast Analyzers are available having either 15-, 16-, or 30-place rotors. To increase the sample analysis rate, an advanced GeMSAEC Fast Analyzer has been designed and fabricated that uses a 42-place rotor. The 42-place rotor, in order to accommodate the increased number of cuvets, is a modified enlargement of the previously described 15-place rotor [N. G. Anderson, Science 166, 317(1969)]. The hardware of the 42-place system is fully compatible with the existing GeMSAEC computer module, and existing software used in the 15-place system has been modified for use with the 42-place system. Results obtained for various chemical and enzymatic analyses are discussed.


Key Words: rapid clinical analysesdedicated computer • FOCAL programsprecisionaccuracylow sample volumelow reagent costs




The following articles in journals at HighWire Press have cited this article: