Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 18: 1334-1338, 1972;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Westgard, J. O.
Right arrow Articles by Birnbaum, M. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Westgard, J. O.
Right arrow Articles by Birnbaum, M. L.

Clinical Chemistry, Vol 18, 1334-1338, Copyright © 1972 by the American Association for Clinical Chemistry

Use of the Du Pont "Automatic Clinical Analyzer" in Direct Determination of Lactic Acid in Plasma Stabilized with Sodium Fluoride

James O. Westgard 1, Brenda L. Lahmeyer 1, and Marvin L. Birnbaum 1

1 Department of Medicine and Clinical Laboratories, University of Wisconsin Center for Health Sciences, Madison, Wis. 53706.

We have studied the determination of lactic acid with the Du Pont ACA and the suitability of plasma as a sample. Blood collected in sodium fluoride/ potassium oxalate Vacutainers and separated in 15 min provided acceptably stable plasma. With a 40-µl sample of plasma, results are linearly related to concentration to 20 mmol/ liter. Standard deviations were 0.16-0.22 mmol/ liter for day-to-day precision. When lactate was added to 53 samples, an average of 99.11% was recovered analytically. Results for plasma lactate (y-axis) agreed with those on plasma filtrates by the Calbiochem "Rapid Lactate" method (n, 92; slope, 1.025; y intercept, -0.086 mmol/liter; standard error, 0.23 mmol/liter). Perchloric acid filtrates can also be analyzed, but fluoride-stabilized plasma is simpler to use.


Key Words: hypoxia • hypoperfusion • perchloric acid as stabilizer • "Stat-Pack" compared • normal values

Submitted on June 15, 1972
Accepted on July 24, 1972




The following articles in journals at HighWire Press have cited this article:


Home page
ANGIOLOGYHome page
R. Kapoor and K. Prasad
Beneficial Effects of Antioxidants in Hemorrhagic Shock
Angiology, April 1, 1995; 46(4): 281 - 297.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
J. B. Gupta, M. Prasad, J. Kalra, and K. Prasad
Platelet-Activating-Factor-Induced Changes in Cardiovascular Function and Oxyradical Status of Myocardium in Presence of the PAF Antagonist CV-6209
Angiology, January 1, 1994; 45(1): 25 - 36.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
R. Kapoor, J. Kalra, and K. Prasad
Beneficial Effects of Methionine on Myocardial Hemodynamic and Cellular Functions in Hemorrhagic Shock
Angiology, April 1, 1992; 43(4): 294 - 305.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
K. Prasad, J. Kalra, and G. Buchko
Acute Hemorrhage and Oxygen Free Radicals
Angiology, January 1, 1988; 39(12): 1005 - 1013.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1972 by the American Association for Clinical Chemistry.