Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 18: 775-777, 1972;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pearson, J. R.
Right arrow Articles by Cooper, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pearson, J. R.
Right arrow Articles by Cooper, D.

Clinical Chemistry, Vol 18, 775-777, Copyright © 1972 by the American Association for Clinical Chemistry

A System for Computer Analysis of Kinetic Enzyme Data from a Modified Beckman DSA-560

J. Richard Pearson 1, Edward R. Pinfield 1, and Daniel Cooper 1

1 Central Laboratory, University of Colorado Medical Center, Denver, Colo. 80220.

We define the following criteria for enzyme assays as being beyond compromise: narrow bandpass double-beam spectrophotometer, multiple readings on the sample (kinetic procedure), temperature control of assay reaction mixture to ±0.1°C, wash-out between samples less than 1% of the preceding sample, and sample size of 100 µl or less. In addition, the following specifications for a system were considered desirable: automatic handling of the sample from initial pipetting through readout, adequate computer compatibility, versatility so that new procedures and different methods could be used, relatively short set-up time, and hard-copy backup in the event the computer failed. We have developed a system for enzyme assays that meets all of the above criteria. It consists of an analyzer (Beckman DSA-560) coupled to two modified Eskalab Spectrophotometers Alpha. The system is controlled via a special-purpose hybrid computer designed and built in our laboratory. Data from the system is analyzed on-line by an IBM 1800 computer. Details of the operation and reliability of the system in a routine clinical chemistry laboratory are discussed.


Key Words: Eskalab colorimeters • GOT and GPT assay • IBM 1800 computer







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1972 by the American Association for Clinical Chemistry.