Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 18: 901-908, 1972;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fasce, C. F.
Right arrow Articles by Vanderlinde, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fasce, C. F., Jr.
Right arrow Articles by Vanderlinde, R. E.

Clinical Chemistry, Vol 18, 901-908, Copyright © 1972 by the American Association for Clinical Chemistry

Factors Affecting the Results of Serum Cholesterol Determinations: An Interlaboratory Evaluation

Charles F. Fasce Jr. 1 and Raymond E. Vanderlinde 1

1 Division of Laboratories and Research, New York State Department of Health, Albany, N. Y. 12201.

We present results of an interlaboratory survey of cholesterol assays in which methodology, standardization technique, type of standard, reagent source, and control sera used are considered. Each of these factors is evaluated, on both clear and icteric sera, with respect to accuracy, interlaboratory precision, and associated random error. We find that most participants use direct techniques, that these laboratories do not use correction procedures where these are needed, and that not all extractants effectively prevent bilirubin interference. Our data illustrate that precision on clear sera is best by direct procedures, but not in the presence of bilirubin. Participants uniformly exhibit better intralaboratory precision than interlaboratory agreement, regardless of the variable being studied. It is appropriate to consider the interactions of variables if a technique is to be properly evaluated.


Key Words: methodology, standardization, standards, reagents, control sera • reagent kits • bilirubin interference • intralaboratory precision

Submitted on October 7, 1971
Accepted on May 19, 1972







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1972 by the American Association for Clinical Chemistry.