Clinical Chemistry, Vol 19, 81-85, Copyright © 1973 by the American Association for Clinical Chemistry
1 From the Laboratory of Applied Studies, Division of Computer
Research and Technology, National Institutes of Health, Public
Health Service, Department of HEW, Bethesda, Md. 20014
The correlation coefficient between two variables (e.g., blood constituents) in normal individuals (or in patients) is usually estimated from measurements of both variables in single samples from the individuals studied. This coefficient is supposed to represent a correlation between the two variables within the average individual. However, unless all the subjects have identical mean values, the "single-sample" coefficient also reflects the correlation of mean values across individuals, generally different from the average intra-individual correlation. Even when both intra-and interindividual correlations are equal, the "single-sample" coefficient underestimates the true intra-individual correlation unless corrected for measurement errors. Using data from normal individuals, two examples are presented: in one case (calcium-total protein), the corrected single-sample coefficient appears to be an unbiased estimate of the desired correlation, whereas in the other example (albumin-globulins), it is quite misleading. These examples support the need for multiple, independent samples from each individual to assure a valid estimate of the average intra-individual correlation between two variables
Accepted on October 31, 1972
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |