Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 19: 459-462, 1973;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Feldman, J. M.
Right arrow Articles by Bowman, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Feldman, J. M.
Right arrow Articles by Bowman, J.

Clinical Chemistry, Vol 19, 459-462, Copyright © 1973 by the American Association for Clinical Chemistry

Urinary Homogentisic Acid: Determination by Thin-Layer Chromatography

Jerome M. Feldman 1 and June Bowman 1

1 From the Division of Endocrinology, Department of Medicine, Duke University Medical Center; and Durham Veterans Administration Hospital, Durham, N. C. 27710.

A new method is described for qualitative and quantitative determination of urinary homogentisic acid. The method involves extraction of urine with ethyl acetate, thin-layer chromatography of the extract on Silica Gel G, elution of the homogentisic acid into water, and color development with Folin’s phenol reagent. Absorbance is maximum at 750 nm and linear to a concentration of at least 5 mg of homogentisic acid per milliliter of urine. The method is highly specific for homogentisic acid; added gentisic acid, 3,4-dihydroxyphenylacetic acid, ascorbic acid, or L-3,4 dihydroxyphenylalanine do not interfere. The coefficient of variation "in-run" is 5.3%, "between-run" 6.8%. Using this method we have demonstrated a marked variation in day-to-day homogentisic acid excretion in a patient with alcaptonuria. This method, which offers some advantages over existing techniques, should be suitable for use in a clinical laboratory.


Key Words: alcaptonuria • inherited metabolic disorders • day-to-day variation

Submitted on December 27, 1972
Accepted on February 9, 1973







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1973 by the American Association for Clinical Chemistry.