Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 19: 832-837, 1973;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maclin, E.
Right arrow Articles by Ansour, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maclin, E.
Right arrow Articles by Ansour, M.

Clinical Chemistry, Vol 19, 832-837, Copyright © 1973 by the American Association for Clinical Chemistry

Relationship between Variables in Instrument Performance and Results of Kinetic Enzyme Assays—A System View

Ernest Maclin 1, Donald Rohlfing 1, and Manoug Ansour 1

1 Electro-Nucleonics, Inc., 368 Passaic Ave., Fairfield, N. J. 07006.

Much effort has been expended to define individual instrumental variables and chemical requirements for kinetic assays. In this paper, these variables are grouped together to demonstrate the relationship between characteristics of the instrument system and final results for kinetic enzyme analyses. Tolerances on instrumental variables are reviewed in terms of these final results, and summarized and interpreted as they effect the results of kinetic assays. We have evaluated the effects on absorbance change as they are related to tolerances for absorbance, time, sample volume, reagent volume, temperature, and path-length. Specifications of spectrophotometric instruments in terms of linearity, accuracy, wavelength adjustability and accuracy, stray light, noise, and drift are also reviewed as to their effects on absorbance change. Generalized data are presented and are then related, as an example, to measurement of aspartate aminotransferase activity.


Key Words: kinetic error analyses • instrumental variables relating to kinetic assays • instrumental tolerances • instrument evaluation

Submitted on April 25, 1973
Accepted on June 11, 1973