Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 19: 853-870, 1973;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leif, R. C.
Right arrow Articles by Thomas, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leif, R. C.
Right arrow Articles by Thomas, R. A.

Clinical Chemistry, Vol 19, 853-870, Copyright © 1973 by the American Association for Clinical Chemistry

Electronic Cell-Volume Analysis by Use of the AMAC I Transducer

R. C. Leif 1 and R. A. Thomas 1

1 Papanicolaou Cancer Research Institute at Miami, Miami, Fla.

A new potential-sensing transducer has been developed that produces short 5- to 10-µs pulses suitable for rapid cell counting and pulse height volume analysis rates. The use of a bridge circuit, where potential-sensing rather than current-carrying electrodes are connected to a differential amplifier with a high common-mode rejection ratio, permitted accurate determination of both pulse width and shapes from the short pulses generated with the transducer. A new sample injection subsystem permits small samples of constant volume to be continuously mixed at a variable rate with a constant flow of diluent. The counting rate can be optimized to 250,000 cells per minute at a 2% coincidence level. Polystyrene latex spheres produced pulses having the five basic shapes predicted by Grover et al. [Biophys. J. 9, 1398 (1969)]. Human erythrocytes produced, in addition to these shapes, a sixth, castle-shaped pulse, presumably caused by rotation or distortion of the erythrocyte as it passes through the orifice. A shape factor has been calculated from the latter pulses. The electronic cell-volume pulses from the tranducer trigger an pulsed-ion laser. The 5-W peak power beam is focused through the orifice. Illumination of the cells with this intense but economical light source permits the combined measurement of electronic cell volume, fluorescence, and light scattering.


Key Words: automated cell counting and classification • laser • scanning electron microscope • Coulter Counter