Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 20: 932-941, 1974;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burtis, C. A.
Right arrow Articles by Mailen, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burtis, C. A.
Right arrow Articles by Mailen, J. C.

Clinical Chemistry, Vol 20, 932-941, Copyright © 1974 by the American Association for Clinical Chemistry

Optimization and Analytical Applications of the Technique of Dynamic Introduction of Liquids into Centrifugal Analyzers

C. A. Burtis 1, W. F. Johnson 1, J. B. Overton 1, T. O. Tiffany 1, and J. C. Mailen 1

1 Molecular Anatomy Program,1 Oak Ridge National Laboratory,2 Oak Ridge, Tenn. 37830.

The technique of dynamically introducing a measured volume of liquid into the spinning rotor of a miniature Centrifugal Fast Analyzer where it is subsequently apportioned into equal aliquots [C. D. Scott and J. C. Mailen, Clin. Chem. 18, 749 (1972)] has been further developed and improved. Several important structural and operational factors have been identified and investigated, including rotor design and geometry, rotor speed, injection volume and rate, and probe diameter. To determine the effect of these factors on the precision and accuracy with which a liquid may be dynamically introduced and apportioned, we developed a dye-dilution procedure. These studies demonstrate that liquid volumes ranging from 10 to 50 µl per cuvet can be dynamically loaded with an accuracy and precision (expressed as standard deviation) of 1 to 2% and 0.5 to 1.1 µl per cuvet, respectively. Several analytical applications of this technique have been investigated: (a) measurement of true sample-blank absorbance before dynamic reagent introduction, (b) sequential reagent addition, (c) correlation studies involving discrete versus dynamic loading of reagent, and (d) reconstitution of lyophilized reagents.


Key Words: determination of enzyme activity, triglycerides, glucose

Submitted on April 5, 1974
Accepted on May 8, 1974