Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 20: 1159-1164, 1974;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berk, L. S.
Right arrow Articles by Nelson, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berk, L. S.
Right arrow Articles by Nelson, J. C.

Clinical Chemistry, Vol 20, 1159-1164, Copyright © 1974 by the American Association for Clinical Chemistry

One-Hour Radioimmunoassay of Serum Drug Concentrations, as Exemplified by Digoxin and Gentamicin

Lee S. Berk 1, John L. Lewis 1, and Jerald C. Nelson 1

1 Departments of Medicine and Radiology, Loma Linda University Medical Center, Loma Linda, Calif. 92354.

Double-antibody radioimmunoassays in which tritium is used for labeling have been adapted for emergency determinations of serum drug concentrations. In the cases of digoxin and gentamicin, the first and second antibody incubations may be carried on simultaneously, minimizing incubation times (10 and 27 min, respectively). Counting the bound radioactivity in solubilized immunospecific precipitates decreases variability in the composition of the phase counted and markedly decreases problems of quenching and chemiluminescence. Logitlog transformation of the sigmoidal standard curve results in a straight line, which can be described by its slope and intercept and which remains constant if assay conditions and critical reagents are held constant. Because the slope and intercept of the standard curve are characteristic of a given assay system, it is possible to calculate the theoretical standard curve for a specific assay system by using the means of previously observed slopes and intercepts. Thus, a separate standard curve need not be prepared for each subsequent assay run. Total time required for drug determinations is now less than 1 h. When unknown samples were measured by both the conventional radioimmunoassay method and the new rapid radioimmunoassay method, the values correlated well (r = 0.99) for both digoxin and gentamicin.


Key Words: tritium-labeled compounds • emergency drug determinations • diagnostic aid • toxicology • double-antibody RIA

Submitted on December 20, 1973
Accepted on June 10, 1974







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1974 by the American Association for Clinical Chemistry.