Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 20: 1217-1221, 1974;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lustgarten, J. A.
Right arrow Articles by Hall, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lustgarten, J. A.
Right arrow Articles by Hall, B.

Clinical Chemistry, Vol 20, 1217-1221, Copyright © 1974 by the American Association for Clinical Chemistry

Evaluation of an Automated Selective-Ion Electrolyte Analyzer for Measuring Na+, K+, and Cl- in Serum

Jack A. Lustgarten 1, Robert E. Wenk 1, Charles Byrd 1, and Barbara Hall 1

1 Clinical Laboratories, Department of Pathology, Sinai Hospital, Baltimore, Md. 21215.

An automated analyzer, in which ion-selective electrodes are used to measure sodium, potassium, and chloride in serum, was assessed in a clinical setting. Day-to-day precision, evaluated by replicate analysis of serum pools, yielded the following coefficients of variation for sodium, potassium, and chloride, respectively: 0.99%, 1.39%, and 0.67%. Values for chloride in both commercial control sera and aqueous standards were linearly related to concentration over a range of at least 10-220 mmol/liter; however, results with the potassium and sodium electrodes showed slight curvilinearity over the range 0-24 and 10-220 mmol/liter, respectively. Mean recoveries for sodium, potassium, and chloride for concentrations covering the clinically important ranges were 98.3-102.3%, 95.9-100.0%, and 97.8-102.0%. The only important differences between experimental and comparison methods in sera were falsely high values obtained with the ion-selective electrode for K+ (caused by supranormal ammonia concentrations) and for Cl- (caused by administered bromide). Mean sodium and chloride values obtained with the electrode did not differ significantly from values obtained by flame-emission photometry or coulometry for duplicate patients’ specimens, but potassium values did differ slightly (P = .05).


Key Words: Stat/Ion • potentiometry • selective ion electrodes for Na, K, Cl • flame-emission photometry • coulometry • inter-method comparisons

Submitted on April 19, 1974
Accepted on July 10, 1974




The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
T. Nakada, K. Zandi-Nejad, Y. Kurita, H. Kudo, V. Broumand, C. Y. Kwon, A. Mercado, D. B. Mount, and S. Hirose
Roles of Slc13a1 and Slc26a1 sulfate transporters of eel kidney in sulfate homeostasis and osmoregulation in freshwater
Am J Physiol Regulatory Integrative Comp Physiol, August 1, 2005; 289(2): R575 - R585.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1974 by the American Association for Clinical Chemistry.