Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 125-129, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nelson, J. W.
Right arrow Articles by Batra, K. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nelson, J. W.
Right arrow Articles by Batra, K. K.

Clinical Chemistry, Vol 21, 125-129, Copyright © 1975 by the American Association for Clinical Chemistry

Simplified Automated Method for Determination of Urinary or Serum Uric Acid, Based on Reduction of Ferric-Phenanthroline Complex

John W. Nelson 1 and K. K. Batra 1

1 Solano Laboratories, 2920 Telegraph Ave., Berkeley, Calif. 94705.

We describe an automated colorimetric method for determination of uric acid in serum or urine by use of an AutoAnalyzer II or SMA 12/60 (Technicon Corp.). The method depends on reduction of a ferric-phenanthroline complex by uric acid under acidic conditions to a ferrous-phenanthroline complex, which absorbs at 505 nm. Advantages of this method over other methods now in use are that color and concentration are linearly related (to 20 mg/100 ml); aqueous reagents are easily prepared, stable, and inexpensive; and interference from ascorbic acid has been eliminated by use of an alkaline copper-containing diluent. The analysis is also free of interference from glucose, creatinine, glutathione, salicylates and hemoglobin. Correlation with results of the Technicon phosphotungstic acid reduction method is excellent (r = .996). Correlation with results of an automated uricase method is satisfactory (r = .979). Recovery of uric acid was 101% over a wide concentration range.