Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 1372-1377, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lutz, R. A.
Right arrow Articles by Flückiger, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lutz, R. A.
Right arrow Articles by Flückiger, J.

Clinical Chemistry, Vol 21, 1372-1377, Copyright © 1975 by the American Association for Clinical Chemistry

Kinetic Determination of Glucose with the GEMSAEC (ENI) Centrifugal Analyzer by the Glucose Dehydrogenase Reaction, and Comparison with Two Commonly Used Procedures

Rudolf A. Lutz 1 and Jürg Flückiger 2

1 Department of Molecular Biology and Biophysics, Swiss Federal Institute of Technology, CH-8049 Zürich, Switzerland.Lab Dr. Otto Lutz AG, Graben 35, CH-8400 Winterthur, Switzerland.
2 Lab Dr. Otto Lutz AG, Graben 35, CH-8400 Winterthur, Switzerland.

A new glucose dehydrogenase preparation has been used to determine the glucose concentration in serum or plasma with the GEMSAEC(ENI) analyzer. The reaction is sufficiently linear to be suitable for a kinetic determination. A sample volume of 15 µl or less is needed, and 14 determinations can be done simultaneously within 160 s (the time needed for loading the samples and reagents into the distribution disc plus a reaction time of 70 s). The reaction is linear up to 300 mg of glucose per 100 ml, but with special computer software linearity could be extended to 1 g of glucose per 100 ml. Day-to-day and within-day precision have been tested with a number of different sera and standards. Accuracy has been checked by comparing the results with those obtained by the hexokinase and the glucose oxidase/peroxidase methods. A better agreement was found with the hexokinase method. The proposed procedure has the advantage of involving only one enzymatic step and of directly measuring reduced coenzyme formation at 340 nm.


Key Words: hexokinase method and glucose oxidase/peroxidase method compared • analytical system

Submitted on February 26, 1975
Accepted on May 23, 1975







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1975 by the American Association for Clinical Chemistry.