Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 1805-1809, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, C. A.
Right arrow Articles by Boguslaski, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, C. A.
Right arrow Articles by Boguslaski, R. C.

Clinical Chemistry, Vol 21, 1805-1809, Copyright © 1975 by the American Association for Clinical Chemistry

Direct Radioimmunoassay for Unconjugated Estriol in Pregnancy Serum, with Use of a Radioiodinated Derivative of Estriol

Carol A. Miller 1, Marion C. Fetter 1, and Robert C. Boguslaski 1

1 Ames Research Laboratory, Ames Co., Division of Miles Laboratories, Inc., Elkhart, Ind. 46514.

We describe a rapid and direct 125I-based radioimmunoassay for quantification of unconjugated (free) estriol in pregnancy serum. Estriol in serum is adsorbed onto a small column of Sephadex, thereby allowing its separation from proteins and interfering materials. A radioiodinated derivative of estriol (6-ketoestriol-6(o-carboxymethyl)oxime-[125I] tyrosine methyl ester) is added to the column, followed by a limiting amount of antiserum. After incubation, the antibody-bound hormone is separated by a buffer wash. The assay exhibits satisfactory recovery and parallelism, and the intraand inter-assay coefficients of variation are <10%. The values obtained by using the assay correlate well (r = 0.97) with those from a comparison method in which solvent extraction and chromatographic purification are used.


Key Words: 125I-based procedure • Sephadex • monitoring fetal status • hormones