Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 420-424, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bucolo, G.
Right arrow Articles by Chang, T. Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bucolo, G.
Right arrow Articles by Chang, T. Y.

Clinical Chemistry, Vol 21, 420-424, Copyright © 1975 by the American Association for Clinical Chemistry

Mechanized Enzymatic Determination of Triglycerides in Serum

Giovanni Bucolo 1, Juanito Yabut 1, and Ting Yen Chang 1

1 Biomedical Research Laboratories, Calbiochem, 10933 N. Torrey Pines Rd., La Jolla, Calif. 92037.

A procedure for enzymatic determination of serum triglycerides [Clin. Chem. 19, 476 (1973)] has been adapted for use in continuous-flow analysis (Technicon AutoAnalyzer). A very simple manifold is used; serum is incubated at 37 °C with the lipase and agr-chymotrypsin in potassium phosphate buffer (0.1 mol/liter, pH 7, containing 1.50 g of bovine serum albumin per liter). The liberated glycerol is dialyzed against the complete glycerol reagent. The change in absorbance at 340 nm resulting from oxidation of NADH is proportional to the dialyzed glycerol. The same manifold can be used to determine preformed glycerol if the hydrolyzing enzymes are omitted. The lipase used need not be extensively purified because the dialyzer removes coloring material and contaminating enzymes that would interfere with the components of the glycerol reagent in the manual procedure. The hydrolysis is complete, as shown by the use of equivalent glycerol standards. No prior treatment of the samples is necessary. Assays are run at 60 per hour in the AutoAnalyzer I, 80 per hour in the AutoAnalyzer II. Results with both instruments for 150 samples correlated well with those obtained by the same enzymatic manual method and by the AutoAnalyzer fluorometric procedure.


Key Words: AutoAnalyzer • glycerol determination

Submitted on June 24, 1974
Accepted on December 24, 1974