Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 533-536, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marcus, M.
Right arrow Articles by Pfeiffer, N. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marcus, M.
Right arrow Articles by Pfeiffer, N. C.

Clinical Chemistry, Vol 21, 533-536, Copyright © 1975 by the American Association for Clinical Chemistry

Micro-Scale Blood Lead Determinations in Screening: Evaluation of Factors Affecting Results

Martin Marcus 1, Melvin Hollander 1, Robert E. Lucas 1, and Norman C. Pfeiffer 1

1 Departments of Pathology and Pediatrics, Fordham Hospital, Misericordia-Fordham Affiliation, Bronx, N. Y. 10458.

The Delves micro-scale technique for blood lead analysis is an accurate method for screening capillary blood specimens, obtained by fingerstick, for lead intoxication. Results are affected by the age of cup, loop, and hollow-cathode tube and by the spatial relationship between optical tube and cup. Because the glass in many commercially available capillary tubes (used in specimen collection) contains lead and cannot be decontaminated, a lead-free glass tube must be used. A solution of citric acid in ethanol (20 g/liter) effectively cleanses the puncture site. A double-blind study of 207 specimens gave a mean value of 276.6 ± 105.8 µg/liter (1 SD) for the micro-scale method vs. 273.2 ± 99.0 for a macro-scale method. The mean coefficent of variation for the micro-scale method was 5.75% ± 1.9 (SD). We conclude that values of 480 µg/liter or below are not "toxic" (i.e., are significantly less than 600 µg/liter, the value at which therapy is begun). The method is shown to be satisfactory as a screening procedure and for confirming lead analyses done by other methods.


Key Words: Delves technique • trace elements • lead poisoning • variation, sources of • collection procedures

Submitted on October 2, 1974
Accepted on January 10, 1975