Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 844-849, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Henry, P. D.
Right arrow Articles by Sobel, B. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Henry, P. D.
Right arrow Articles by Sobel, B. E.

Clinical Chemistry, Vol 21, 844-849, Copyright © 1975 by the American Association for Clinical Chemistry

Rapid Separation of Plasma Creatine Kinase Isoenzymes by Batch Adsorption on Glass Beads

Philip D. Henry 1, Robert Roberts 1, and Burton E. Sobel 1

1 Department of Medicine, Cardiovascular Division, Barnes Hospital, Washington University School of Medicine, 660 S. Euclid Ave., St. Louis, Mo. 63110.

To separate the MM and MB creatine kinase (EC 2.7.3.2) isoenzymes in small plasma samples, we developed a simple, rapid ion-exchange batch-adsorption procedure with "DEAE Glycophase" glass beads (Corning). All separative steps are performed in a single test tube and can be completed within a few minutes. Results of measurements of isoenzymes in plasma samples from patients with acute myocardial infarction were compared to those obtained with an independent quantitative assay method previously reported. Additional measurements were performed on standard plasma samples containing mixtures of MM and MB isoenzyme purified from human myocardium. Results by the two independent assay procedures agreed well, as did measured isoenzyme activities and activities predicted from the amounts of isoenzyme added. Activities in the fractions containing separated isoenzymes were measured by a direct kinetic fluorometric assay. MB activities in normal plasma averaged 1.6 ± 0.28 U/liter (mean ± SD).


Key Words: electrophoresis • fluorometry • enzyme activity • heart disease • myocardial infarction • inter-method comparison

Submitted on January 17, 1975
Accepted on March 19, 1975




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
R. Rej
Clinical Chemistry through Clinical Chemistry: A Journal Timeline
Clin. Chem., December 1, 2004; 50(12): 2415 - 2458.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
P. R. Puleo, D. Meyer, C. Wathen, C. B. Tawa, S. Wheeler, R. J. Hamburg, N. Ali, S. D. Obermueller, F. J. Triana, J. L. Zimmerman, et al.
Use of a Rapid Assay of Subforms of Creatine Kinase MB to Diagnose or Rule Out Acute Myocardial Infarction
N. Engl. J. Med., September 1, 1994; 331(9): 561 - 566.
[Abstract] [Full Text]


Home page
ANN INTERN MEDHome page
J. FERLINZ
Recognition and Management of Expanding Myocardial Infarction
Ann Intern Med, January 1, 1988; 108(1): 131 - 134.
[Abstract] [PDF]


Home page
Arch Intern MedHome page
H. D. Strauss and R. Roberts
Plasma MB Creatine Kinase Activity and Other Conventional Enzymes: Comparison in Patients With Chest Pain and Tachyarrhythmias
Arch Intern Med, March 1, 1980; 140(3): 336 - 339.
[Abstract] [PDF]


Home page
ScienceHome page
R Roberts, B. Sobel, and C. Parker
Radioimmunoassay for creatine kinase isoenzymes
Science, November 19, 1976; 194(4267): 855 - 857.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1975 by the American Association for Clinical Chemistry.