Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 21: 1093-1101, 1975;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Norris, K. A.
Right arrow Articles by Smith, W. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Norris, K. A.
Right arrow Articles by Smith, W. G.

Clinical Chemistry, Vol 21, 1093-1101, Copyright © 1975 by the American Association for Clinical Chemistry

Colorimetric Enzymatic Determination of Serum Total Carbon Dioxide, as Applied to the Vickers Multichannel 300 Discrete Analyzer

Kenneth A. Norris 1, Alan R. Atkinson 1, and William G. Smith 1

1 Vickers Limited Medical Engineering, Priestley Road, Basingstoke RG24 9NP, Hampshire, U. K.

Phosphoenolpyruvate carboxylase (EC 4.1.1.31) has been used in developing a simple, inexpensive colorimetric assay for serum total carbon dioxide in an open system. The oxaloacetate formed by the action of the enzyme on bicarbonate and phosphoenolpyruvate is measured by use of the diazonium salt of Fast Violet B. Interferences from bilirubin, pyruvate, and drugs are negligible. Acetoacetate interference is significant only in highly ketotic samples, and a serum blank corrects for it. Serum protein interference is equivalent to 3.3 ± 1.25 mmol of CO2 per liter and hence is sufficiently constant to be corrected for by use of a serum standard or serum blank. The method has been applied to the Vickers M-300 and D-300 systems and within-batch standard deviations of ±0.1 to ±0.6 mmol/liter have been observed. Excellent correlation with orthodox techniques has been obtained.


Key Words: blood gases • inter-method comparison • discrete analyzers • continuous-flow analysis

Submitted on February 10, 1975
Accepted on April 16, 1975




The following articles in journals at HighWire Press have cited this article:


Home page
NDT PlusHome page
S. D. Navaneethan, R. Mooney, and J. Sloand
Pseudo-anion gap acidosis
NDT Plus, April 1, 2008; 1(2): 94 - 96.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1975 by the American Association for Clinical Chemistry.