Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 22: 1579-1588, 1976;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Richmond, W
Right arrow Search for Related Content
PubMed
Right arrow Articles by Richmond, W

Clinical Chemistry, Vol 22, 1579-1588, Copyright © 1976 by American Association for Clinical Chemistry

Use of cholesterol oxidase for assay of total and free cholesterol in serum by continuous-flow analysis

W Richmond

Idescribe an assay for total cholesterol in serum, with use of the AutoAnalyzer ii (Technicon), in which cholesterol esters are saponified by alkali, cholesterol is held in aqueous micellar solution with a surfactant (Triton X-100) and oxidized by cholesterol oxidase, and the hydrogen peroxide produced is measured by chelation with Ti4+ and xylenol orange. An assay for free cholesterol in serum, based on similar principles, is also described, and the two can be run simultaneously on a dual-channel AutoAnalyzer II. Standard solutions of cholesterol in isopropanol have poorer carryover characteristics than sera, and therefore do not reach the same continuous-flow steady state as sera of equivalent concentrations. Consequent potential calibration errors are avoided by using micellar solutions of cholesterol containing albumin for standardization. The formation of cholesterol peroxide in solutions of cholesterol in isopropanol is demonstrated, and this constitutes another potential source of error in the calibration of enzymic cholesterol assays. In analyzing patients' sera, results of the total cholesterol assay correlate well with those of a mechanized method in which cholesterol esterase and cholesterol oxidase are used; an automated Abell method, calibrated with solutions of cholesterol in isopropanol, gave slightly higher values. Determinations of the ratio of free cholesterol to total cholesterol by our automated cholesterol exidase assays given values that agree well with published results in which digitonin precipitation is used.


The following articles in journals at HighWire Press have cited this article:


Home page
Ann Clin BiochemHome page
O. Ozcan, O. M. Ipcioglu, M. Gultepe, and C. Basoglu
Altered red cell membrane compositions related to functional vitamin B12 deficiency manifested by elevated urine methylmalonic acid concentrations in patients with schizophrenia
Ann Clin Biochem, January 1, 2008; 45(1): 44 - 49.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
T. Hayashi, T. Esaki, E. Muto, H. Kano, Y. Asai, N. K. Thakur, D. Sumi, M. Jayachandran, and A. Iguchi
Dehydroepiandrosterone Retards Atherosclerosis Formation Through Its Conversion to Estrogen : The Possible Role of Nitric Oxide
Arterioscler. Thromb. Vasc. Biol., March 1, 2000; 20(3): 782 - 792.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1976 by the American Association for Clinical Chemistry.