Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 22: 299-304, 1976;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cheung, M.
Right arrow Articles by Slaunwhite, W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Cheung, M.
Right arrow Articles by Slaunwhite, W., Jr

Clinical Chemistry, Vol 22, 299-304, Copyright © 1976 by American Association for Clinical Chemistry

Use of polyethylene glycol in separating bound from unbound ligand in radioimmunoassay of thyroxine

MC Cheung and WR Slaunwhite Jr

In most rapid radioimmunoassay methods, absorbents are used that disturb the equilibrium of the ligand-antibody interaction; thus the separation process must be rigidly timed. We show here that polyethylene glycol (mol wt. 6000) abolishes this constant. We measured gamma-globulin precipitation by polyethylene glycol (150g/liter) in a thyroxine radioimmunoassay system involving use of a sheep anti- thyroxine antiserum, quantitatively and qualitatively, with either normal human serum or completely precipitated at pH 6-9 at 4 and 25 degrees C, but incompletely if salt concentration was high (1 mol/liter). Specificity of gamma-globulin precipitation increased with increasing pH and temperature. All gamma-globulin-bound thyroxine was precipitated, and also some not bound to gamma-globulin. This was taken into account by including "blank" tubes (no antibody, but with normal sheep serum) in all assays. Because this reaction is predominantly entropic and temperature independent, the entire procedure can be done at 37 degrees C and room temperature without rigid timing. The assay requires 10 mul of serum, its reproducibility is 4-8% (CV) in the euthyroid and hyperthyroid range, and its accuracy is close to 100%.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1976 by the American Association for Clinical Chemistry.