Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 22: 663-666, 1976;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gerron, G.
Right arrow Articles by Rudman, D
Right arrow Search for Related Content
PubMed
Right arrow Articles by Gerron, G.
Right arrow Articles by Rudman, D

Clinical Chemistry, Vol 22, 663-666, Copyright © 1976 by American Association for Clinical Chemistry

Technical pitfalls in measurement of venous plasma NH3 concentration

GG Gerron, JD Ansley, JW Isaacs, MH Kutner and D Rudman

Measurement of venous plasma NH3 in normal subjects by the ion-exchange method of Forman [Clin. Chem. 10, 497 (1964)] in a hospital clinical laboratory gave a mean value of 640 mug/liter (range, 300-1320 mug/liter; intraassay, intra-individual, and inter-individual coefficients of variation, 8, 47, and 47%, respectively). The following conditions adversely affect the reproducibility of the test: pollution of laboratory atmosphere and glassware by NH3-containing detergents; smoking by patient or analyst; delay, turbulence, or use of heparin lock in venipuncture; delay or warming of plasma above degrees C before mixing it with resin; and delay in colorimetric analysis of resin eluate. When these sources of error were eliminated, the mean value for normals was reduced to 330 mug/liter, the range was narrowed to 220-470 mug/liter, and the above-mentioned CV's were 5, 16, and 17%, respectively. With the precautions cited, furthermore, the intra-assay and intra-individual CV's for fasting NH3 concentration in cirrhotic patients were similarly reduced. An NH3 tolerance test was done by administering a standard dose of NH4Cl to patients and measuring venous plasma NH3 at 0, 15, 30, 60, and 90 min; the NH3 tolerance was quantified from the area under the curve relating concentration to time (mug - min/liter). As measured in the clinical laboratory, NH3 tolerance of cirrhotic patients showed intra-assay and intra-individual CV's of 50 to 90%. When the tolerance tests were repeated in the same subjects with the laboratory precautions listed above, these CV's were reduced to 8-15%.