Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 23: 50-59, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kirkpatrick, A.
Right arrow Articles by Nakamura, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kirkpatrick, A.
Right arrow Articles by Nakamura, R. M.

Clinical Chemistry, Vol 23, 50-59, Copyright © 1977 by American Association for Clinical Chemistry

Comparison of double-antibody radioimmunoassay with Farr-technique radioimmunoassay and double-antibody enzyme immunoassay for alpha- fetoprotein

A Kirkpatrick, HT Wepsic and RM Nakamura

We describe double-antibody procedures for determining alpha- fetoprotein in human serum. An equilibrium procedure can be done in 24 h with a sensitivity of at least 4 mug/liter and coefficient of variation of 5.5%. There are no interferences from normal human sera or sera with certain commonly seen chemical abnormalities. We also describe and discuss sequential procedures that range in sensitivity from 250 ng to 1mug/liter and require 24-48h incubation. The precise (mid-range)portion of the dose/response curve for sequential procedures can be shifted to higher or lower values by an adjustment of the time of preliminary incubation of antibody with unlabeled antigen. With a 37 degrees C incubation, a sequential procedure can be completed in 7 h. Sensitivity is 1 mug/liter, and coefficient of variation 8.0%. The relative merits of the above assay procedures are discussed. The double- antibody redioimmunoassay is twice as sensitive as the Farr procedure [J. Infect. Dis. 103, 239 (1958)], and it is free of the large and variable nonspecific precipitation that accompanies the precipitation of bound antigen with sodium sulfate solution. Double-antibody radioimmunoassay is superior to enzyme immunoassay in both sensitivity and precision.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1977 by the American Association for Clinical Chemistry.