Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 23: 1819-1825, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frye, R.
Right arrow Articles by Rock, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frye, R.
Right arrow Articles by Rock, R. C.

Clinical Chemistry, Vol 23, 1819-1825, Copyright © 1977 by American Association for Clinical Chemistry

A semi-automated fluorometric method for total estrogens in pregnancy urine

R Frye, PF Fong, GF Johnson and RC Rock

We report a continuous-flow fluorometric method for total urinary estrogens that involves the Kober reaction, with extraction of the reaction product into dichloroethane containing trichloroacetic acid as described by Hahnel and Jones [Clin. Chim. Acta 16, 185 (1967)]. The dichloroethane extraction gives greater stability to the Kober color and sharper separation of aqueous and organic phases. The analytical system is adjusted to give maximum response to estriol 16alpha,beta-D- glucuronide, the principal estrogen conjugate in urine from late pregnancy, when calibrated with estriol standards. An initial 20-fold dilution of the sample with water increased analytical recovery of estriol conjugates from urine while maintaining adequate fluorescent response. Glucose interference was reduced by dilution and eliminated by treatment with sodium borohydride. Urinary protein up to 20 g/liter did not interfere. Total estriol, as determined by gas-liquid chromatography, comprises about 70% of total urinary estrogens in late pregnancy as measured by our continuous-flow fluorometric method. A reference range is presented based on 209 randomly collected urine specimens in which total urinary estrogens are expressed as a ratio to creatinine.