Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 23: 1984-1988, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Krstulovic, A. M.
Right arrow Articles by Champlin, P. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Krstulovic, A. M.
Right arrow Articles by Champlin, P. B.

Clinical Chemistry, Vol 23, 1984-1988, Copyright © 1977 by American Association for Clinical Chemistry

High-performance liquid-chromatographic analysis for tryptophan in serum

AM Krstulovic, PR Brown, DM Rosie and PB Champlin

Concentrations of total tryptophan were determined rapidly and sensitively in 50 microliter of serum by a reversed-phase partition version of high-performance liquid chromatography. For determination of total tryptophan, sample preparation requires only precipitation of the serum protein with trichloroacetic acid and removing excess trichloroacetic acid with a 1,1,2-trichlorotrifluoroethane(Freon)/tri-N- octylamine solution. Tryptophan in serum samples was detected by ultraviolet and fluorescence spectrometry. No interferences from the naturally occurring constituents of serum were observed. Elution time for tryptophan is 15 min, the limit of detection is 1 pmol.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Am. Coll. Nutr.Home page
J. B. Lasekan, W. W. K. Koo, J. Walters, M. Neylan, and S. Luebbers
Growth, tolerance and biochemical measures in healthy infants fed a partially hydrolyzed rice protein-based formula: a randomized, blinded, prospective trial.
J. Am. Coll. Nutr., February 1, 2006; 25(1): 12 - 19.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1977 by the American Association for Clinical Chemistry.