Clinical Chemistry 23: 2242-2246, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peele, J. D.
Right arrow Articles by Crews, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peele, J. D., Jr
Right arrow Articles by Crews, R.

Clinical Chemistry, Vol 23, 2242-2246, Copyright © 1977 by American Association for Clinical Chemistry

Semi-automated vs. visual reading of urinalysis dipsticks

JD Peele Jr, RH Gadsden and R Crews

Semi-automated reflectance readings of urinalysis dipsticks showed better precision than visual readings in the case of artificially prepared urine samples containing glucose, ketone, and protein. Actual pathological specimens containing glucose, protein, and nitrite also showed that instrumental readings were better than visual. Results of repeated visual readings spread over three different color blocks for certain concentrations of glucose, ketone, and protein, whereas repeated instrumental readings were never spread greater than two color blocks. Subjectivity can be reduced by semi-automated dipstick urinalysis.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
P. Froom, R. Etzion, and M. Barak
What Is an Abnormal Test Strip Urinary Erythrocyte Concentration?
Clin. Chem., March 1, 2004; 50(3): 673 - 675.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Penders, T. Fiers, and J. R. Delanghe
Quantitative Evaluation of Urinalysis Test Strips
Clin. Chem., December 1, 2002; 48(12): 2236 - 2241.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Froom, B. Bieganiec, Z. Ehrenrich, and M. Barak
Stability of Common Analytes in Urine Refrigerated for 24 h before Automated Analysis by Test Strips
Clin. Chem., September 1, 2000; 46(9): 1384 - 1386.
[Abstract] [Full Text] [PDF]