Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 23: 806-810, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mason, R. S.
Right arrow Articles by Posen, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mason, R. S.
Right arrow Articles by Posen, S.

Clinical Chemistry, Vol 23, 806-810, Copyright © 1977 by American Association for Clinical Chemistry

Some problems associated with assay of 25-hydroxycalciferol in human serum

RS Mason and S Posen

Methods available for the assay of 25-hydroxycalciferol in human serum are evaluated and compared to one another. Ethanol was chosen for use in the initial extraction procedure and rat-kidney cytosol as the binding protein, although good alternative methods are also available. We used silicic acid for chromatography and found this an essential step. Reproducibility was increased when, after "bound" and "free" material were separated, an aliquot of the supernate was pipetted into the counting vial instead of the entire supernatant fluid being decanted. Beta-lipo-protein added to the assay system was of no advantage; added bovine serum albumin interfered with the assay by giving rise to high blank values. With ethanol extraction, silicic acid chromatography, rat kidney cytosol and separation on dextran-coated charcoal, sera from normal subjects showed a mean 25-hydroxycalciferol concentration of 28.5 microng/liter (range, 13.1 to 43.9) during the fall season. Coefficients of variation for a control serum were 4.9% (intra-assay) and 10.9% (interassay).


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
C. Lind, J. Chen, and I. Byrjalsen
Enzyme immunoassay for measuring 25-hydroxyvitamin D3 in serum
Clin. Chem., June 1, 1997; 43(6): 943 - 949.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1977 by the American Association for Clinical Chemistry.