Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 23: 1556-1562, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leon, L. P.
Right arrow Articles by Horvath, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leon, L. P.
Right arrow Articles by Horvath, C.

Clinical Chemistry, Vol 23, 1556-1562, Copyright © 1977 by American Association for Clinical Chemistry

Continuous-flow analysis for glucose, triglycerides, and ATP with immobilized enzymes in tubular form

LP Leon, M Sansur, LR Snyder and C Horvath

Small-bore ("Autozyme") tubes with immobilized enzymes at the inner wall have been developed and studied for application in the Technicon "SMAC" high-speed continuous-flow biochemical analyzer. Tubes coated with glucose oxidase (D-glucose:oxygen oxidoreductase, EC 1.1.3.4) have been prepared for the assay of glucose, with colorimetric assay of the hydrogen peroxide produced; tubes coated with glycerol kinase (ATP:glycerol phosphotransferase, EC 2.7.1.30) for the enzymatic assay of triglycerides; tubes coated with hexokinase (ATP:D-hexose-6- phosphotransferase, EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (D-glucose-6-phosphate:NAD+ oxidoreductase EC 1.1.1.49) for the measurement of ATP, an intermediate product in assays for creatine kinase. With use of 10-15 cm lengths of Autozyme tube and SMAC hydraulics (150 samples per hour), assay sensitivity and carryover were similar to values for the corresponding free-enzyme methods. These immobilized enzymes were sufficiently stable for one to eight weeks of continuous use before replacemnt. We conclude that suitable bound- enzyme tubes can replace either single or multiple free-enzyme reagents in many continuous-flow assays at high sampling rates.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1977 by the American Association for Clinical Chemistry.