Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 23: 1648-1653, 1977;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Green, D.
Right arrow Articles by Reynolds, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Green, D.
Right arrow Articles by Reynolds, N.

Clinical Chemistry, Vol 23, 1648-1653, Copyright © 1977 by American Association for Clinical Chemistry

Double-antibody radioimmunoassay for factor VIII-related antigen

D Green and N Reynolds

A plasma protein required for the support of ristocetin-induced platelet aggregation was isolated from antihemophilic factor concentrate and radiolabeled with 125I. A double-antibody radioimmunoassay was developed, with use of specific rabbit anti-VIII related antigen serum and goat anti-rabbit globulin. The assay is sensitive, reproducible, and technically simple to perform. Values obtained in normal subjects ranged from 0.65 to 1.53 units, similar to our normal range for VIII coagulant activity (0.67-1.43 units). However, normal or increased values of VIII-related antigen were observed in VIII coagulant-deficient hemophiliacs. Also, concentrations of VII-related antigen significantly exceeded coagulant concentrations in several patients with liver disease or disseminated intravascular coagulation, or both. Of a broad selection of congenital coagulation disorders examined, only patients with von Willebrand's disease had decreased VIII-related antigen concentrations, and these corresponded to the lowered concentration of ristocetin cofactor in the patients. In three transfused patients, VII-related antigen values correlated with the concentration of the cofactor. Our results suggest that the radioimmunoassay of VIII-related antigen is a simple and valuable adjunct in the study of patients with clotting abnormalities.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1977 by the American Association for Clinical Chemistry.