Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1948-1953, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Proelss, H. F.
Right arrow Articles by Miles, D. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Proelss, H. F.
Right arrow Articles by Miles, D. G.

Clinical Chemistry, Vol 24, 1948-1953, Copyright © 1978 by American Association for Clinical Chemistry

High-performance liquid-chromatographic simultaneous determination of commonly used tricyclic antidepressants

HF Proelss, HJ Lohmann and DG Miles

We report a method for simultaneous measurement of five commonly used tricyclic antidepressant drugs (doxepin, desipramine, nortriptyline, imipramine, and amitriptyline) in serum by paired-ion high-performance liquid chromatography, with use of a reversed-phase column and ultraviolet detection at 254 nm. The drugs are extracted from 2 ml of serum at pH 14 into hexane/isoamyl alcohol (99/1 by vol) and re- extracted into 200 microliter of 0.1 mol/liter HCI. An aliquot of the aqueous acid phase is chromatographed with use of a methanol/acetonitrile/water (41/15/44) solvent system, containing 5 mmol of pentanesulfonic acid per liter of phosphate buffer (0.1 mol/liter, pH 6.5), at a flow rate of 1,5 ml/min. Analytical recoveries of the drugs from serum increase with increasing concentration, from 62% at 25 microgram/liter to 93% at 300 microgram/liter. Linear response is observed for drug concentrations up to 1500 microgram/liter and the detection limit is 2-3 microgram/liter. Within-run precision ranges from 1.4 to 2.9% and day-to-day precision from 1.7 to 7%, depending on the specific drug. The entire procedure can be completed within 45 min and is well adapted to the routine clinical laboratory. Of 48 common basic and several neutral drugs tested for possible interferences, only three benzodiazepines, three phenothiazines, and three antihistamines interfere with the assay of doxepin, desipramine, and nortriptyline, respectively.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
R. Rej
Clinical Chemistry through Clinical Chemistry: A Journal Timeline
Clin. Chem., December 1, 2004; 50(12): 2415 - 2458.
[Abstract] [Full Text] [PDF]


Home page
Arch Gen PsychiatryHome page
A. H. Oliveto, A. Feingold, R. Schottenfeld, P. Jatlow, and T. R. Kosten
Desipramine in Opioid-Dependent Cocaine Abusers Maintained on Buprenorphine vs Methadone
Arch Gen Psychiatry, September 1, 1999; 56(9): 812 - 820.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS