Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1966-1970, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frank, J. J.
Right arrow Articles by Watkins, B. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frank, J. J.
Right arrow Articles by Watkins, B. F.

Clinical Chemistry, Vol 24, 1966-1970, Copyright © 1978 by American Association for Clinical Chemistry

Effect of in vitro hemolysis on chemical values for serum

JJ Frank, EW Bermes, MJ Bickel and BF Watkins

Hemolysis in serum specimens is commonplace. This study examines the effect of hemolysis on results of selected chemical assays. Hemolysis was simulated by adding hemolysate to serum to give hemoglobin concentrations of 90 to 2800 mg/liter and a rating by technologists of 0 to 4 + hemolyzed. The effect of hemolysis on values for some serum constituents, particularly acid phosphatase and creatine kinase, was shown to be method dependent. Not unexpectedly, hemolysis most affects results for lactate dehydrogenase.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
B. Mensel, U. Wenzel, M. Roser, J. Ludemann, and M. Nauck
Considerably Reduced Centrifugation Time without Increased Hemolysis: Evaluation of the New BD Vacutainer(R) SSTTMII Advance
Clin. Chem., April 1, 2007; 53(4): 794 - 795.
[Full Text] [PDF]


Home page
Int J EpidemiolHome page
S. Clark, L. D Youngman, A. Palmer, S. Parish, R. Peto, and R. Collins
Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies
Int. J. Epidemiol., February 1, 2003; 32(1): 125 - 130.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Hawkins
Variability in Potassium/Hemoglobin Ratios for Hemolysis Correction
Clin. Chem., May 1, 2002; 48(5): 796 - 796.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
Z. Ma, T. G. Monk, L. T. Goodnough, A. McClellan, M. Gawryl, T. Clark, P. Moreira, P. E. Keipert, and M. G. Scott
Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests
Clin. Chem., September 1, 1997; 43(9): 1732 - 1737.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.