Clinical Chemistry, Vol 24, 1966-1970, Copyright © 1978 by American Association for Clinical Chemistry
JJ Frank, EW Bermes, MJ Bickel and BF Watkins
Hemolysis in serum specimens is commonplace. This study examines the effect of hemolysis on results of selected chemical assays. Hemolysis was simulated by adding hemolysate to serum to give hemoglobin concentrations of 90 to 2800 mg/liter and a rating by technologists of 0 to 4 + hemolyzed. The effect of hemolysis on values for some serum constituents, particularly acid phosphatase and creatine kinase, was shown to be method dependent. Not unexpectedly, hemolysis most affects results for lactate dehydrogenase.
The following articles in journals at HighWire Press have cited this article:
![]() |
B. Mensel, U. Wenzel, M. Roser, J. Ludemann, and M. Nauck Considerably Reduced Centrifugation Time without Increased Hemolysis: Evaluation of the New BD Vacutainer(R) SSTTMII Advance Clin. Chem., April 1, 2007; 53(4): 794 - 795. [Full Text] [PDF] |
||||
![]() |
S. Clark, L. D Youngman, A. Palmer, S. Parish, R. Peto, and R. Collins Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies Int. J. Epidemiol., February 1, 2003; 32(1): 125 - 130. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Hawkins Variability in Potassium/Hemoglobin Ratios for Hemolysis Correction Clin. Chem., May 1, 2002; 48(5): 796 - 796. [Full Text] [PDF] |
||||
![]() |
Z. Ma, T. G. Monk, L. T. Goodnough, A. McClellan, M. Gawryl, T. Clark, P. Moreira, P. E. Keipert, and M. G. Scott Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests Clin. Chem., September 1, 1997; 43(9): 1732 - 1737. [Abstract] [Full Text] [PDF] |
||||