Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 2042-2043, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Emanuel, R. L.
Right arrow Articles by Williams, G. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Emanuel, R. L.
Right arrow Articles by Williams, G. H.

Clinical Chemistry, Vol 24, 2042-2043, Copyright © 1978 by American Association for Clinical Chemistry

Should blood samples for assay of plasma renin activity be chilled?

RL Emanuel and GH Williams

Collecting blood on ice for renin determination reportedly may produce falsely high results. To assess the probability of this occurring under actual collection conditions, we measured renin activity in duplicate aliquots of plasma from blood samples from 25 hypertensive patients, both supine and upright, and in 10 supine normotensive controls. One aliquot of the blood was collected on ice and processed at 4 degrees C, the other at room temperature. The two aliquots showed no significant differences in renin activity. If anything, values for samples collected at room temperature were higher. Repeat determination on the same specimens stored at--20 degrees C for nine and 12 months revealed no significant changes in results for any samples, although the amount of angiotensin I found in the sample before incubation at 37 degrees C significantly increased. We conclude that it makes little difference at what temperature one collects blood for renin determination, but because of the wide fluctuations in "room" temperature we recommend that blood samples be collected on ice.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
J. H. A. Roding, T. Weterings, and C. van der Heiden
Plasma Renin Activity: Temperature Optimum at ~45 {degrees}C
Clin. Chem., July 1, 1997; 43(7): 1243 - 1244.