Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 2139-2144, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maeda, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maeda, H.

Clinical Chemistry, Vol 24, 2139-2144, Copyright © 1978 by American Association for Clinical Chemistry

Assay of an antitumor protein, neocarzinostatin, and its antibody by fluorescence polarization

H Maeda

I evaluated use of the fluorescence polarization technique to measure neocarzinostatin, a proteinaceous antitumor antibiotic, and its antibody, in serum. The antigen (neocarzinostatin), labeled with fluorescein isothiocyanate, was allowed to interact with its antibody in a cuvet, in the instrument, yielding an increase in the fluorescence polarization value. Antibody content was determined in the presence of a definite amount of the labeled antigen, fluorescence polarization values increasing in parallel with each addition of antibody. Antigen content was determined with a known amount of antibody, which reacted at first with an unknown amount of antigen in samples, followed by addition of a definite amount of the labeled antigen (competition). I used the method to determine a pharmacokinetic parameter, the apparent volume of distribution for neocarzinostatin in rabbits, using drug- injected rabbit sera. I evaluated precision, accuracy, and reproducibility, using various samples or possible interfering substances such as bilirubin and hemoglobin, and also compared results for antigen with those by single radial immunodiffusion assay. The present assay is fast (less than 2 min), sensitive (less than 10 nmol/liter can be detected), and simple (there is no separation step before readout of the results).


The following articles in journals at HighWire Press have cited this article:


Home page
Journal of Bioactive and Compatible PolymersHome page
A. Kobayashi, T. Oda, and H. Maeda
Protein Binding of Macromolecular Anticancer Agent SMANCS: Characterization of Poly(styrene-co-maleic acid) Derivatives as an Albumin Binding Ligand
Journal of Bioactive and Compatible Polymers, January 1, 1988; 3(4): 319 - 333.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.