Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 2155-2157, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peeters, T. L.
Right arrow Articles by Vantrappen, G. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peeters, T. L.
Right arrow Articles by Vantrappen, G. R.

Clinical Chemistry, Vol 24, 2155-2157, Copyright © 1978 by American Association for Clinical Chemistry

Radioimmunoassay for urinary lysozyme in human serum from leukemic patients

TL Peeters, YR Depraetere and GR Vantrappen

We present a radioimmunoassay for lysozyme in human serum, based upon human lysozyme isolated from the urine of leukemic patients and antiserum prepared against this lysozyme in the goat. In the separation step, a second antibody is used. By properly adjusting the concentrations of unlabeled and 125I-labeled lysozyme and of the antibodies, maximal precision (SD, 0.04 mg/litre) was obtained in the range 0.00 to 2.00 mg/litre. In 20 normal volunteers the lysozyme concentration was 4.6 +/- 0.8 mg/litre (mean +/- SD), in 13 patients with monocytic leukemia 34.4 +/- 8.6 mg/litre. Correlation with lysoplate determinations was excellent in leukemic sera (r = 0.97) but was poor in normal sera (r = 0.35), possibly owing to the existence of isoenzymes.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
P. Montagne, M. L. Cuilliere, C. Mole, M. C. Bene, and G. Faure
Microparticle-enhanced nephelometric immunoassay of lysozyme in milk and other human body fluids
Clin. Chem., August 1, 1998; 44(8): 1610 - 1615.