Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 2161-2165, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meiattini, F.
Right arrow Articles by Tarli, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meiattini, F.
Right arrow Articles by Tarli, P.

Clinical Chemistry, Vol 24, 2161-2165, Copyright © 1978 by American Association for Clinical Chemistry

The 4-hydroxybenzoate/4-aminophenazone chromogenic system used in the enzymic determination of serum cholesterol

F Meiattini, L Prencipe, F Bardelli, G Giannini and P Tarli

A single reagent, containing cholesterol oxidase, cholesterol esterase, peroxidase, 4-hydroxybenzoate, and 4-aminophenazone, is used in determining serum cholesterol. Analysis time is 15 min, and the standard curve is linear to 6.0 g/liter. Analytical recovery of cholesterol was 100.1 +/- 0.4%. Within-run precision (CV) was less than or equal to 1.4 1.4%, between-run less than or equal to 4.8%. Comparison with results by a Liebermann Burchard method [Clin. Chim. Acta 5, 637 (1960)] gave a linear regression of y = 1.08x--0.05, with a correlation coefficient (r) of 0.985. Comparison with the Roeschlau enzymic method [J. Clin. Chem. Clin. Biochem, 12, 226 (1974)] gave y = 1.02x + 0.01 (r = 0.958). Comparison with the enzymic method of Allain et al. [Clin. Chem. 20, 470 (1974)] gave y = 1.01x--0.00 (r = 0.995). The following substances do not interfere up to the indicated concentrations (mg/liter): hemoglobin (5000), bilirubin (100), reduced glutathione (150), l-cysteine (400), urea (3000), creatinine (200), uric acid (200), d-glucose (10000), L-ascorbic acid (50), acetylsalicylic acid (500), L-DOPA (10), ergothioneine (1000), 2,5- dihydroxybenzoic acid (20), and 3,4-dihydroxybenzoic acid (10). Stored in an amber-colored bottle, the working reagent is stable for three months at 2--8 degrees C and for three weeks at 25 degrees C.