Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 2192-2196, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baril, L.
Right arrow Articles by Carmel, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baril, L.
Right arrow Articles by Carmel, R.

Clinical Chemistry, Vol 24, 2192-2196, Copyright © 1978 by American Association for Clinical Chemistry

Comparison of radioassay and microbiological assay for serum folate, with clinical assessment of discrepant results

L Baril and R Carmel

Folate assays by use of radiolabeled folate provide obvious practical advantages over the standard microbiological assay, but remain incompletely tested. We therefore compared results for 415 sera with a kit involving 3H-labeled folate and the Lactobacillus casei microbiological method. We examined the patients' data when there were discrepancies between the two methods. Although the correlation overall was satisfactory, results were discrepant in 25% of cases. In 74% of the latter, the radioassay result appeared to be the correct one, primarily because L. casei results were suppressed by antibiotics being taken by the patient. The radioassay occasionally gave falsely high values for patients with liver disease and falsely low ones for patients who had received isotopes for scanning purposes. Several assay kits that make use of 125I- or 75Se-labeled folate were also tested. Although these results correlated with the results of 3H-labeled folate assay, various problems appeared, including the possible need for serum- supernate control tubes in one kit. Answers to these and other questions and careful clinical correlation of results are needed for any folate radioassays before their adoption for routine clinical use.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.