Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 330-338, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ahmed, S.
Right arrow Articles by Cooper, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ahmed, S.
Right arrow Articles by Cooper, G.

Clinical Chemistry, Vol 24, 330-338, Copyright © 1978 by American Association for Clinical Chemistry

Analytical performance and comparability of the determination of triglycerides by 12 Lipid Research Clinic laboratories

S Ahmed, K Lippel, P Bachorik, J Albers, J Williams and G Cooper

Twelve Lipid Research Clinic laboratories performed automated fluorometric triglyceride analyses on four control serum pools of known concentration by a modified Hantzsch reaction. The analyses were done during a two-year period, with use of common standards, methodology, and quality-control procedures. Estimates of analytical bias, variability, and short- and long-term trends for each instrument and for the entire group of LRC instruments are presented. High accuracy, precision, and interlaboratory comparability were achieved through rigorous standardization and control of the entire analytical procedure. Individual instrument biases varied from an average of 4.9% below to 1.0% above reference values. Between-run variability was often less than within-run variability and interlaboratory variation was substantially less than intralaboratory variation. The total standard deviation for all instruments ranged from 37 to 63 mg/liter. Only 5 to 14% of this variation was due to differences among instruments. The among-instruments standard deviation ranged from 12 to 17 mg/liter; the between-run, within-instrument standard deviation ranged from 29 to 46 mg/liter, and within-run standard deviation from 27 to 40 mg/liter. The significance of the results for long-term collaborative studies is discussed.


The following articles in journals at HighWire Press have cited this article:


Home page
JAMAHome page
B. M. Rifkind and P. Segal
Lipid Research Clinics Program Reference Values for Hyperlipidemia and Hypolipidemia
JAMA, October 14, 1983; 250(14): 1869 - 1872.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.