Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1335-1342, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Curme, H. G.
Right arrow Articles by Wu, T. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Curme, H. G.
Right arrow Articles by Wu, T. W.

Clinical Chemistry, Vol 24, 1335-1342, Copyright © 1978 by American Association for Clinical Chemistry

Multilayer film elements for clinical analysis: general concepts

HG Curme, RL Columbus, GM Dappen, TW Eder, WD Fellows, J Figueras, CP Glover, CA Goffe, DE Hill, WH Lawton, EJ Muka, JE Pinney, RN Rand, KJ Sanford and TW Wu

Dry, thin films containing all necessary reagents for clinical analysis by colorimetry have been designed. Reagents in a matrix of hydrophilic polymer are coated on top of a transparent plastic base. A white isotropically porous polymer spreading layer, 80% void volume, is coated over the reagent layer(s). In the analysis, a drop (typically 10 microliter) of undiluted serum or other fluid is touched to the spreading layer. The fluid spreads rapidly and uniformly through the pore structure, filling a void volume corresponding to the drop volume. Water and low-molecular-weight components diffuse from the spreading layer into the reagent layer(s), initiating the reaction sequence. The spreading layer acts also as a white optical diffuser for reflection densitometry. Optical reflection density is linearized through use of the function developed by Williams and Clapper [J. Opt. Soc. Am. 43, 595 (1953)] to convert reflection to transmission density. A wide variety of chemical assays are compatible with this format. As an example, for the glucose film we found coefficients of variation of 1.5% in predicting glucose concentrations in control sera during 20 days. Results for glucose concentrations in several hundred patients' sera by the present method were very cose to those obtained with the Center for Disease Control's hexokinase reference method.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
R. Rej
Clinical Chemistry through Clinical Chemistry: A Journal Timeline
Clin. Chem., December 1, 2004; 50(12): 2415 - 2458.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
S. Julien, J. Laine, and J. Morisset
Regulation of Rat Pancreatic CCKB Receptor and Somatostatin Expression by Insulin
Diabetes, June 1, 2004; 53(6): 1526 - 1534.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Fingerhut
Determination of Cerebrospinal Fluid Glucose with the Vitros DT60 II Dry Chemistry System
Clin. Chem., September 1, 1998; 44(9): 2000 - 2001.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
H. Curme and R. N. Rand
Early history of Eastman Kodak Ektachem slides and instrumentation
Clin. Chem., September 1, 1997; 43(9): 1647 - 1652.
[Full Text] [PDF]


Home page
ScienceHome page
R. Elin
Instrumentation in clinical chemistry
Science, October 17, 1980; 210(4467): 286 - 289.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.