Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1393-1398, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barabino, R. C.
Right arrow Articles by Keyes, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barabino, R. C.
Right arrow Articles by Keyes, M. H.

Clinical Chemistry, Vol 24, 1393-1398, Copyright © 1978 by American Association for Clinical Chemistry

Coupled reactions of immobilized enzymes and immobilized substrates: clinical application as exemplified by amylase assay

RC Barabino, DN Gray and MH Keyes

We described a partitioned enzyme-sensor system, which incorporates an immoblized substrate and three or more discrete immobilized enzymes. This instrument measures alpha-amylase activity by passing the solution containing alpha-amylase over a column packed with immobilized starch. The resulting oligosaccharides are successively exposed to a column or columns containing immobolized glucose oxidase, catalase, glucoamylase or maltase, and glucose oxidase. The resulting hydrogen peroxide is detected by a three-electrode amperometric cell. All immobilized reagents were immobilized on a particulate, porous alumina to allow rapid and constant flow rate. With use of less than optimum immobilized reagents, alpha-amylase activity has been measured from about 5 to 200 kU/liter with a 50 microliter sample size. Lack of sensitivity is predominantly attributable to the low activity and low stability of immobilized maltase and glucoamylase. We believe that a clinical test using this system is feasible and desirable because the immobilized reagent system should allow for testing of alpha-amylase with excellent precision, convenience to the operator, and low cost.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.