Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1414-1419, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rehak, N. N.
Right arrow Articles by Young, D. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rehak, N. N.
Right arrow Articles by Young, D. S.

Clinical Chemistry, Vol 24, 1414-1419, Copyright © 1978 by American Association for Clinical Chemistry

Prospective applications of calorimetry in the clinical laboratory

NN Rehak and DS Young

Calorimetric analysis depends on the direct proportionality between the heat changes that occur during chemical reactions and the amount of reacting substances. Potential uses of calorimetry in the clinical laboratory are discussed, with examples. The calorimetric technique does not require optically clear specimens, and if the specificity of the measured reaction is assured, calorimetry can be used for quantitative determinations of components that are present in a complex matrix system such as body fluids. Specific enzymic reactions have been used to measure substrates and enzyme activities in biological specimens calorimetrically, with precision, sensitivity, and accuracy comparable to routine photometric techniques. The application of calorimetry in the clinical laboratory is limited now by its slowness, but development of automated instruments may enable the technique to become competitive with conventional analytical techniques in the clinical laboratory.


The following articles in journals at HighWire Press have cited this article:


Home page
Appl. Environ. Microbiol.Home page
S. Zhang, O. Norrlow, and E. S. Dey
Improvement of NaNO2-Oxidizing Activity in Nitrobacter vulgaris by Coentrapment in Polyacrylamide Containing Polydimethylsiloxane Copolymer and DEAE-Sephadex
Appl. Envir. Microbiol., October 1, 2005; 71(10): 5888 - 5892.