Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1477-1484, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lippel, K.
Right arrow Articles by Winn, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lippel, K.
Right arrow Articles by Winn, C.

Clinical Chemistry, Vol 24, 1477-1484, Copyright © 1978 by American Association for Clinical Chemistry

External quality-control survey of cholesterol analyses performed by 12 lipid research clinics

K Lippel, S Ahmed, JJ Albers, P Bachorik, R Muesing and C Winn

We report accuracy and precision achieved in the automated analysis for cholesterol in a long-term multilaboratory study, presenting and evaluating the significance of data accumulated by 12 Lipid Research Clinics (LRC's) in the analysis of 18 unknown surveillance pools during three years. The average bias for all pools and for 13 autoAnalyzer II (Technicon Instruments Corp., Tarrytown, N.Y. 10591) instruments in the 12 clinics was -0.41% (range -1.2 to +0.3%), as compared to values established by reference methodology. The regression equation relating observed cholesterol values (y) to reference values (x) was: y = 0.35 + 0.977x. The bias varied from pool to pool (-2.3 to +5.3%), positive biases being observed for pools with cholesterol concentrations less than 1.4 g/liter, and negative biases for those pools with higher concentrations. Total standard deviations ranged between 25 and 75 mg/liter, and total CV's for most individual instruments were between 1 and 3%. Of the variability for a particular pool, less than 20% was due to differences among instruments, and within- and between-run variabilities were approximately equal. These trends were the same as those previously observed [Clin. Chem. 23, 1744 (1977)] in the analysis of bench control pools of known cholesterol concentration.


The following articles in journals at HighWire Press have cited this article:


Home page
JAMAHome page
C. L. Johnson, B. M. Rifkind, C. T. Sempos, M. D. Carroll, P. S. Bachorik, R. R. Briefel, D. J. Gordon, V. L. Burt, C. D. Brown, K. Lippel, et al.
Declining Serum Total Cholesterol Levels Among US Adults: The National Health and Nutrition Examination Surveys
JAMA, June 16, 1993; 269(23): 3002 - 3008.
[Abstract] [PDF]


Home page
JAMAHome page
B. M. Rifkind and P. Segal
Lipid Research Clinics Program Reference Values for Hyperlipidemia and Hypolipidemia
JAMA, October 14, 1983; 250(14): 1869 - 1872.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS