Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 24: 1578-1585, 1978;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lolekha, P. H.
Right arrow Articles by Wongvibulsin, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lolekha, P. H.
Right arrow Articles by Wongvibulsin, A.

Clinical Chemistry, Vol 24, 1578-1585, Copyright © 1978 by American Association for Clinical Chemistry

New continuous-flow analysis for simultaneous determination of creatinine and uric acid in 200 microliters of serum without use of a dialyzer

PH Lolekha, V Chantarothipol and A Wongvibulsin

We present a new method for direct continuous-flow (AutoAnalyzer II) measurement of serum creatinine and uric acid. The manifold is simple, inexpensive, and can be constructed in the laboratory. Only 200 microliters of serum is needed; analysis rate is 60 samples per hour. The incorporation of sodium dodecyl sulfate and the simultaneous provision of blank subtraction make it possible to omit the dialysis step. Our method does not require the linearizer, since instrument response and concentration of creatinine and uric acid are linearly related to 200 and 120 mg/liter, respectively. The percentages of steady state, interaction, and recovery are acceptable, Precision is excellent and the results obtained from the new method correlate well with those obtained by the comparison methods. Interferences are few and, when encountered, are generally smaller than in the modified Technicon method. Marked hemolysis interferes only with the uric acid assay; marked turbidity has no effect on results for creatinine. Icteric serum with total bilirubin of 50 and 100 mg/liter interferes significantly with results for creatinine and uric acid, respectively, by the new method.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1978 by the American Association for Clinical Chemistry.