Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 25: 1826-1830, 1979;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bolton, A. E.
Right arrow Articles by Challand, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bolton, A. E.
Right arrow Articles by Challand, G. S.

Clinical Chemistry, Vol 25, 1826-1830, Copyright © 1979 by American Association for Clinical Chemistry

Three different radioiodination methods for human spleen ferritin compared

AE Bolton, V Lee-Own, RK McLean and GS Challand

We compared three different methods for radioiodination of human spleen ferritin. Tracers prepared by direct oxidative iodination with use of Chloramine T or 1,3,4,6-tetrachloro-3 alpha, 6 alpha-diphenylglycoluril (Iodogen) were structurally altered by the labeling procedure, as was made apparent by gel filtration and electrophoresis on polyacrylamide gel. Tracers prepared by conjugation to radioiodinated N-succinimidyl-6- (4-hydroxyphenyl)propionate retained their structural integrity, as assessed by physicochemical methods. Such tracers bound more than 90% in antibody excess, yielded self-displacement curves parallel to unlabeled ferritin standards, and retained their immunoreactivity for nine weeks. By contrast, immunological activity and stability of tracers prepared by the oxidative methods were less satisfactory. Tracers prepared by using lodogen were unsuitable for use in the ferritin radioimmunoassay because of shallow standard-inhibition curves and poor binding in the absence of added standard. Thus, we found the conjugation procedure to be the most suitable of the three methods for preparation of spleen-ferritin tracers.


The following articles in journals at HighWire Press have cited this article:


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
P. Thiagarajan, A. Le, and C. R. Benedict
{beta}2-Glycoprotein I Promotes the Binding of Anionic Phospholipid Vesicles by Macrophages
Arterioscler. Thromb. Vasc. Biol., November 1, 1999; 19(11): 2807 - 2811.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1979 by the American Association for Clinical Chemistry.